GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Ivory

Roll over image to zoom in

Eaton SGF15V-SP GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Ivory

Item #: SGF15V-SP by Cooper Wiring Devices

UPC #: 032664742415

Item Discontinued!
See reviewsSee reviews

The item is currently out of stock and it may or may not be restocked
OUT OF STOCK

Shop with Confidence

30 Days Easy Return. We are the largest supplier of the most adaptable, personalized hardware in the industry. We work hard to ensure you're satisfied with our products.

Features
  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or "end of life" condition
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Ground termination with back wire clamp provides secure wiring and reduces installation time
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide great aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
  • Line-load miswiring protection

Mounting Type

Wall

Material

Polypropylene

Dimensions

4.2 in L x 1.68 in W x 1.27 in D

Color

Ivory

Operating Temperature

-35 to 66 deg C

Wire Size

14 to 10 AWG

NEMA Configuration

5-15R

Number of Poles

2

Number of Wires

3

Frequency Rating

60 Hz

Nomenclature

SGF15V-SP RCPT DPLX GFCI15A IV

Wiring Type

Back Side

Current Rating

15 A

Product Overview
RCPT DPLX GFCI ST 15A/125V IV
Specifications:

Application: For commercial, industrial and institutional uses areas like public bathrooms, breakrooms and food service areas

Includes: Wallplate

Eaton's Arrow Hart line of GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. GFCIs provide state-of-the-art, dependable electrical shock protection. In addition to being tested to the highest standards to help ensure safety, Arrow Hart GFCIs will deny power and prevent re-setting if the device is no longer able to provide safe, protected power.