Features

Function

Power Supply

ADA Approved

False

Product Type

Access Control

Series

Access Control Peripheral

Manufacturer Parent

Altronix

Enclosure Style

BC300 Enclosed

Output Type

Dual Voltage

Battery Included

No

Class 2 Output Limited

Yes

Power Supply Type

Switching

Sub-Series

AL-EFLOW6N8D

Fuse Size

5A

ADA Compliant

No

Operating Temperature

32 to 120°F

Number of Outputs

8 Foot (96 Inches)

Visual Indicators

AC Power; AC Input and DC Output Indicators

Standards

UL294 Listed; UL603 Listed; UL1069 Listed; UL1481 Listed; cUL Listed For ULC-S318-96; California State Fire Marshal Approved; CE Compliant

Rated Voltage

12/24VDC

Fire Alarm Interface

Yes

Battery Type

Lead Acid; Gel

Features

Overvoltage Protection; Built-in Charger; Automatic Switch Over; Battery Fail, Battery Presence, Notification Trigger, Low Power Shutdown and AC Fail Supervision; Fire Alarm Disconnect

Fuse Type

PTC

Product Dimensions

13" x 13-1/2" x 3-1/4"

Battery Backup

YES

Input Voltage

115VAC

Product Overview
eFlow6N SeriesPower Supply/Chargers

Altronix eFlow6N series power supply/chargers convert a 120VAC 60Hz input into a single, eight (8) or sixteen (16) fused outputs or PTC protected Class 2 power-limited outputs. Power supply/charger is selectable for 12VDC or 24VDC with a total of 6A max. supply current. It also offers a suite of features that includes fire alarm disconnect, overvoltage protection, and low power disconnect which prevents deep discharge of stand-by batteries.

Key Features:
  • Available with 1, 8 or 16 outputs
  • Fused outputs or PTC protected Class 2 power-limited outputs.
  • Additional aux. Class 2 power-limited output rated @ 1A
  • Overvoltage protection
  • Fire alarm disconnect
Supervision:
  • AC Fail
  • Battery Fail and Battery Presence
  • Low power shutdown
  • Built-in charger for sealed lead acid or gel type batteries
  • Instantaneous transfer to stand-by batteries
  • Short circuit and overload protection
  • AC input and DC output LED indicators
  • UL Listed in the U.S. and Canad
  • CE Approved
  • Lifetime Warranty / Made in the U.S.A
Specifications: Input:
  • Voltage - 120VAC, 60Hz, 3.5A max.
  • Fusing - 5A / 250V.
Outputs:
  • Voltage - 12VDC or 24VDC selectable.
  • Current - 6A continuous max.
  • Protection - Fused 2.5A / PTC 2A.
  • Auxiliary - Class 2 power-limited @ 1A (unswitched).
  • Other - Overvoltage protection. Filtered and regulated.
Back-up Battery (not included):
  • Capacity
    • - 7AH / 12VDC (1 or 2 within enclosure).
    • - 12AH / 12VDC (requires larger "X" enclosure).
    • - 40AH, 65AH (requires separate enclosure).
  • Type - Sealed lead acid or gel type.
  • Fuse - Rating 10A @ 32VDC.
  • Failover - Upon AC loss, instantaneous.
Fire Alarm Disconnect:
  • Supervised - Latching or non latching.
  • EOL - 10K Resistor.
Supervision:
  • AC Failure - Form "C" contacts.
  • Battery - Form "C" contacts.
  • Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
Indicators (LED):
  • Input - 120VAC is present.
  • DC Output - Powered.
Agency Listings: UL:
  • UL294 - Access Control System Units.
  • UL603 - Power Supplies for Use with Burglar-Alarms Systems.
  • UL1481 - Power Supplies for Fire Protective Signaling Systems.
cUL:
  • ULC-S318-96 - Power Supplies for Burglar Alarm Systems. Also suitable for Access Control.
  • CSFM - California State Fire Marshall Approved.
  • CE - European Conformity
Physical and Environmental: eFlow6N, eFlow6N8(D), eFlow6N16(D):
  • 13.5" x 13" x 3.25" (H x W x D)
  • (342.9mm x 330.2mm x 82.55mm)
eFlow6NX, eFlow6NX8(D), eFlow6NX16(D):
  • 15.5" x 12" x 4.5" (H x W x D)
  • (393.7mm x 304.8mm x 114.3mm)
Temperature:
  • Operating - 32°F to 120°F (0°C to 49°C).
  • Storage - -4°F to 158°F (-20°C to 70°C).
Relative Humidity:
  • 85% +/-5%
BTU/Hr. (approx.):
  • 12VDC: 37 BTU/Hr
  • 24VDC: 74 BTU/Hr
Product Weight / Shipping (approx.): eFlow6N:
  • Product Weight - 6.5 lbs. (2.95 kg)
  • Shipping Weight - 7.4 lbs (3.3 kg))
eFlow6NX:
  • Product Weight - 8.55 lbs. (3.88 kg)
  • Shipping Weight - 9.65 lbs (4.38 kg)
eFlow6N8(D):
  • Product Weight - 6.65 lbs. (3.02 kg)
  • Shipping Weight - 7.55 lbs (3.42 kg)
eFlow6NX8(D):
  • Product Weight - 8.5 lbs. (3.86 kg)
  • Shipping Weight - 9.6 lbs (4.35 kg)
eFlow6N16(D):
  • Product Weight - 6.8 lbs. (3.08 kg)
  • Shipping Weight - 7.7 lbs (3.49 kg)
eFlow6NX16(D):
  • Product Weight - 8.65 lbs. (3.92 kg)
  • Shipping Weight - 9.75 lbs (4.42 kg)
Accessories: Network Supervision:
  • Altronix model LINQ2 Network Communication Module provides remote supervision, control and monitoring over LAN/WAN
    • - Remotely reports accurate power diagnostics
    • - Controls power and resets devices
    • - Reports system diagnostics via Email